Galil DMC-1400 Manual De Usuario
88 ● ET
DMC-1400 Series Command Reference
ET
FUNCTION:
Electronic cam table
DESCRIPTION:
The ET command sets the ECAM table entries for the slave axis. The values of the master are
not required. The slave entry (n) is the position of the slave when the master is at the
point (n
point (n
∗ i) + o, where i is the interval and o is the offset as determined by the EP
command.
ARGUMENTS: ET [n] = m
where
n is an integer between 0 and 256
m is an integer in the range between -2,147,438,648, and 2,147,438,647
USAGE:
While Moving
Yes
Default Value
In a Program
Yes
Default Format
Command Line
Yes
Can be Interrogated
No
Used as an Operand
No
Controller Usage ALL
RELATED COMMANDS:
Enable Ecam
Engage Ecam
Specify Ecam Cycle
Specify Ecam intervals and starting point
Ecam quit
EXAMPLES:
ET [7] = 1000
Specifies the position of the slave that must be synchronized with the
eighth increment of the master.