5-31
Catalyst 3750-X and 3560-X Switch Software Configuration Guide
OL-21521-01
Chapter 5      Managing Switch Stacks
Troubleshooting Stacks
On a Catalyst 3750-E or 3750-X switch:
Switch# show platform stack ports buffer 
 
              Stack Debug Event Data Trace 
==============================================================
Event type LINK: Link status change
Event type RAC: RAC changes to Not OK
Event type SYNC: Sync changes to Not OK
==============================================================
 
  Event    Stack           Stack PCS Info              Ctrl-Status  Loopback   Cable
  Count    Port                                                     IOS / HW   length
=========  =====  ===================================  ===========  ========  ======== 
Event type: LINK OK Stack Port 1
0000000153   1    FF01FF00 860351A5 55A5FFFF FFFFFFFF   0CE60C10     No /No   50 cm   
0000000153   2    FF01FF00 00017C07 00000000 0000FFFF   0CE60C10     No /No   3 m     
Event type: RAC
0000000154   1    FF01FF00 860351A5 55A5FFFF FFFFFFFF   0CE60C10     No /No   50 cm   
0000000154   2    FF01FF00 00017C85 00000000 0000FFFF   0CE60C10     No /No   3 m 
Hardware Loop Example: LINK NOT OK Event
On a Catalyst 3750 switch:
Switch# show platform stack ports buffer 
              Stack Debug Event Data Trace 
==============================================================
Event type LINK: Link status change
Event type RAC: RAC changes to Not OK
Event type SYNC: Sync changes to Not OK
==============================================================
  Event    Stack           Stack PCS Info              Ctrl-Status  Loopback   Cable
  Count    Port                                                     IOS / HW   length
=========  =====  ===================================  ===========  ========  ======== 
Event type: LINK OK Stack Port 2
0000000005   1    FF08FF00 0001FBD3 0801080B EFFFFFFF   0C100CE6     No /No   No cable
0000000005   2    FF08FF00 8603E4A9 5555FFFF FFFFFFFF   0C100CE6     No /No   50 cm   
Event type: RAC
0000000006   1    FF08FF00 0001FC14 08050204 EFFFFFFF   0C100CE6     No /No   No cable
0000000006   2    FF08FF00 8603E4A9 5555FFFF FFFFFFFF   0C100CE6     No /No   50 cm   
Event type: LINK NOT OK Stack Port 2
0000000939   1    FF08FF00 00016879 00010000 EFFFFFFF   0C100C14     No /No   No cable
0000000939   2    FF08FF00 0001901F 00000000 FFFFFFFF   0C100C14     No /No   No cable
Event type: RAC
0000000940   1    FF08FF00 000168BA 00010001 EFFFFFFF   0C100C14     No /No   No cable
0000000940   2    FF08FF00 0001905F 00000000 FFFFFFFF   0C100C14     No /No   No cable
Event type: LINK OK Stack Port 1
0000000956   1    FF08FF00 86034DAC 5555FFFF FFFFFFFF   1CE61CE6     Yes/Yes  No cable
0000000956   2    FF08FF00 86033431 55AAFFFF FFFFFFFF   1CE61CE6     Yes/Yes  No cable
Event type: LINK OK Stack Port 2
0000000957   1    FF08FF00 86034DAC 5555FFFF FFFFFFFF   1CE61CE6     Yes/Yes  No cable
0000000957   2    FF08FF00 86033431 55AAFFFF FFFFFFFF   1CE61CE6     Yes/Yes  No cable
Event type: RAC
0000000958   1    FF08FF00 86034DAC 5555FFFF FFFFFFFF   1CE61CE6     Yes/Yes  No cable
0000000958   2    FF08FF00 86033431 55AAFFFF FFFFFFFF   1CE61CE6     Yes/Yes  No cable