Cisco Systems 3560X Manual De Usuario

Descargar
Página de 1438
 
5-33
Catalyst 3750-X and 3560-X Switch Software Configuration Guide
OL-21521-01
Chapter 5      Managing Switch Stacks
Troubleshooting Stacks
Switch#/  Stack   Neighbor   Cable    Link   Link   Sync      #         In
 Port#     Port              Length    OK   Active   OK    Changes   Loopback
          Status                                          To LinkOK
--------  ------  --------  --------  ----  ------  ----  ---------  --------
  1/1       OK       2      50 cm     Yes    Yes    Yes        1        No  
  1/2     Absent    None    No cable   No     No     No        2        No   
  2/1      Down     None    50 cm      No     No     No        2        No   
  2/2       OK       1      50 cm     Yes    Yes    Yes        1        No   
Only one end of the cable connects to a stack port, Port 1 on Switch 2.
  •
The Stack Port Status value for Port 2 on Switch 1 is Absent, and the value for Port 1 on Switch 2 is 
Down
.
  •
The Cable Length value is No cable.
Diagnosing the problem:
  •
Verify the cable connection for Port 2 on Switch 1. 
  •
Port 2 on Switch 1 has a port or cable problem if
  –
The In Loopback value is Yes.
or
  –
The Link OKLink Active, or Sync OK value is No.
Fixing a Bad Connection Between Stack Ports
Stack cables connect all members. Port 2 on Switch 1 connects to Port 1 on Switch 2. 
This is the port status:
Switch# show switch stack-ports summary
Switch#/  Stack   Neighbor   Cable    Link   Link   Sync      #         In
 Port#     Port              Length    OK   Active   OK    Changes   Loopback
          Status                                          To LinkOK
--------  ------  --------  --------  ----  ------  ----  ---------  --------
  1/1       OK       2      50 cm     Yes    Yes    Yes       1          No   
  1/2      Down     None    50 cm      No     No     No       2          No   
  2/1      Down     None    50 cm      No     No     No       2          No   
  2/2       OK       1      50 cm     Yes    Yes    Yes       1          No
Diagnosing the problem:
  •
The Stack Port Status value is Down.
  •
Link OK
Link Active, and Sync OK values are No.
  •
The Cable Length value is 50 cm. The switch detects and correctly identifies the cable.
The connection between Port 2 on Switch 1 and Port 1 on Switch 2 is unreliable on at least one of the 
connector pins.