Chapter 37      Configuring the Switch Fabric Module
Configuring the Switch Fabric Module
When configuring the switching mode, note the following syntax information:
  •
To allow use of nonfabric-enabled modules or to allow fabric-enabled modules to use bus mode, 
enter the fabric switching-mode allow bus-mode command.
  •
To prevent use of nonfabric-enabled modules or to prevent fabric-enabled modules from using bus 
mode, enter the no fabric switching-mode allow bus-mode command.
Caution
When you enter the no fabric switching-mode allow bus-mode command, power is removed from any 
nonfabric-enabled modules installed in the switch.
  •
To allow fabric-enabled modules to use truncated mode, enter the fabric switching-mode allow 
truncated
 command.
  •
To prevent fabric-enabled modules from using truncated mode, enter the no fabric switching-mode 
allow truncated
 command.
  •
To configure how many fabric-enabled modules must be installed before they use truncated mode 
instead of bus mode, enter the fabric switching-mode allow truncated threshold number command.
  •
To return to the default truncated-mode threshold, enter the no fabric switching-mode allow 
truncated threshold
 command.
Configuring Fabric-Required Mode
Note
The commands in this section are supported only with Release 12.1(11b)E and later.
To configure fabric-required mode, which prevents all switching modules from operating unless there is 
a Switch Fabric Module installed, perform this task:
Caution
If you enter the fabric required command on a switch that does not have a Switch Fabric Module 
installed, all modules except the supervisor engine turn off.
When configuring fabric-required mode, note the following syntax information:
  •
If you boot the switch with fabric-required mode configured but without a Switch Fabric Module 
installed, only the supervisor engine receives power; no switching modules power up.
  •
When the switch is operating with fabric-required mode configured and a Switch Fabric Module 
installed, if you remove the switch fabric module or if it fails, the switch removes power from all 
switching modules; only the supervisor engine remains active.
  •
When the switch is operating with fabric-required mode configured and with redundant Switch 
Fabric Modules installed, if you remove both switch fabric modules or if both fail, the switch 
removes power from all switching modules; only the supervisor engine remains active.
Command
Purpose
Router(config)# fabric required 
Configures fabric-required mode, which prevents switching 
modules from operating without a switch-fabric module.
Router(config)# no fabric required 
Clears fabric-required mode.