3com CM 4000 Manual De Usuario

Descargar
Página de 709
Control Panel Operation
VGA Display
6−139
CM 4000 Installation and Operating Manual
The following discussion is based on the factory default set of display pages.
SWITCHER OUTPUT STATUS PAGE
Thomson
        WXYZ TELEVISION FACILITY CONTROL SYSTEM               PAGE: 01
May 10, 1999             MAIN Switcher Output Status                    12:34:56
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
OUTPUT      VIDEO     LEFT     RIGHT    TC
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
PrdA        VT01      VT01     VT01     VT01
PrdB        VC01      VC01     VC01
PrdC        Cam1      Cam1     Cam1
Figure 6−171. Switcher out-
put status page (example)
Levels
Outputs
Inputs
A switcher output status page (Figure 6−171) can provide a list of switcher outputs and the name of the input switched to each.
Separate columns for each level can be used to report split switches; these can be highlighted with a distinct color.
An alternating (flashing) display indicates that the output is locked or protected:
The first flashing character shows “L” if the output is locked; “P” if the output is protected.
If a single flashing character is shown next, it indicates a special control device (i.e., not an MPK panel) has set
the the lock or protect. “A” is for an ASCII protocol device (e.g., an automation computer); “S” is for an ES−
switch protocol device (ditto).
The following characters show the name of the locking/protecting device. The name is taken from (or short-
ened from) that shown on the MPK Devices table.
NEXT is used to cycle through additional logical switchers (if any). UP and DOWN (or the arrow buttons on the CP 3020)
will step through additional pages of outputs; hold the key down to auto−repeat.
Cursor Mode − Selecting an Output for Control
To enter cursor mode, press SELECT on the CM 4000 (or CURSOR MODE on the CP 3020). This will cause
the name of the first output to appear in reverse video. The UP and DOWN buttons (or arrow buttons) will move
the cursor from one output to another. An output pointed to by the cursor is automatically selected as the output
to be controlled by the CP 3000 Switcher Control Panel associated with the CM 4000 providing the VGA display.
Note 1: If an output cannot be switched, it may be that the output or input requested is not included in the CP
Output Set assigned to the CP 3000. See page 5−114. This may also be the case if asterisks appear in place of
the normal status indication.