Optiquest iRIS 320 Manual De Usuario

Descargar
Página de 73
 iRIS 220 / iRIS 320, V1.19 User Guide - 10 
 
10
 
iQuest (NZ) Ltd  - PO Box 15169, Hamilton, New Zealand  Tel: +64 7 857-0810  Fax: +64 7 857-0811  Email: iquest@iquest.co.nz
 
 
2.8 Key Features 
 
2.8.1 Terminal Configuration 
All configuration and set-up parameters are modified via a standard ASCII terminal connected to the RS232 
serial interface.  This means that the user can configure the device without needing specialised configuration 
software  installed  on  their  computer  specifically  for  this  purpose.    iQuest  also  supply  a  network  based 
terminal program (UDPTerminal) that allows set-up to be performed across the GPRS/CDMA-1X network via 
ASCII socket A. Refer to Section 4.2 for details on the terminal setup. 
  
 
2.8.2 Wireless IP Connectivity (GPRS/CDMA) 
Wireless  Internet  Protocol  connectivity  is  provided  via  an  on-board  modem.    Through  this  interface  it  is 
possible to perform configuration changes and retrieve logged data.  To facilitate GPRS connectivity with the 
GSM  models,  a  suitably  activated  SIM  card  must  be  inserted  in  the  device.    For  all  models,  it  is  also 
necessary  to  program  the  unit  with  appropriate  GPRS/CDMA-1X  connection  settings  via  a  terminal 
connected to the RS232 serial interface.  
 
The  iRIS  communicates  over  a  GPRS  or  CDMA-1X  network  using  UDP  protocol  via  two  concurrent  data 
ports.    Port  A  is  used  for  ASCII  communication  and  provides  similar  terminal  functionality  to  that  available 
through the RS232 serial interface.  Port B is used for proprietary System DO
 (binary) communication and 
supports time series data retrieval and unsolicited alarm call-in to a HydroTel™ 2000 base station. This port 
is  also  used  for  auto  reporting  of  data  to  a  suitable  base  station  such  as  the  iQuest  Data  Network 
(
http://data.iquest.co.nz
), when the iRIS has been configured to use this mode. 
  
 
2.8.3 Alternative Wireless Connectivity (CSD/SMS) 
Two other wireless connection modes other than GPRS/CDMA-1X are also possible. These are CSD (Circuit 
Switched  Data)  or  SMS  (Short  Message  Service).    As  with  the  GPRS/CDMA-1X  mode  described  above  in 
Section 2.8.2, using either CSD and/or SMS requires either a SIM card with relevant services enabled by the 
GSM service provider, or in the case of CDMA-1X, the appropriate services enabled by the CDMA provider. 
 
The CSD option is achieved by establishing a dial-up modem connection across the GSM or CDMA network. 
Once  this  link  is  connected,  data  retrieval  and  configuration  can  be  performed  in  a  similar  manner  to  the 
GPRS/CDMA-1X mode.  
 
The  SMS  option  works  by  sending  a  preset  text  message  to  up  to  two  destination  cellphones  or  SMS 
receivers.  This  message contains  the  iRIS  site  identification and  the current  values  of  all enabled sensors. 
See Section 5.3 for more information on using the SMS feature. 
 
NOTE: No matter what the modem callback mode is set to (GPRS/CDMA-1X or  CSD or SMS), the iRIS 
will answer any incoming CSD calls and also respond to incoming SMS requests as long as it is not 
connected  using  the  wireless  IP  link.  The  modem  callback  mode  setting  only  changes  the  service 
that  is  used to  notify an alarm  or  generate  a communication  test.    In this  case  the selected  service 
and destination phone number is used to call a base modem (CSD) or send a text message (SMS). 
 
 
2.8.4 Power Management 
The iRIS supports three power management modes: 
 
No Power Save 
With  power  management  disabled,  the  internal  wireless  modem  is  maintained  in  a  powered  on  state 
whenever  a  GPRS/CDMA-1X  or  CSD  session  is  not  currently  active.    While  in  this  state,  periodic  signal 
strength  measurements  are  made  and  it  is  possible  to  interrogate  the  internal  modem  using  the  AT 
command set via a terminal connected to the serial interface. 
 
All on-board communication, I/O and status LED’s are permanently enabled in this mode.