In a Managed System
 
In a managed MSH chassis, operation of the Switch 1005 is the same, 
 
but the Management Module may itself override the link settings. This 
 
will occur if:
 
The Management Module has a stored configuration for a Switch 1005 
 
in that slot, and the stored backplane settings are different from the set 
 
on the Switch 1005
 
The Management Module derives default backplane settings that are 
 
different from the set on the Switch 1005
 
If the Management Module has no stored configuration data for the 
 
Switch 1005, it will apply the following default backplane settings:
 
the first Switch 1005 detected in the chassis will have all backplane 
 
ports enabled.
 
subsequent Switch 1005 modules will have only the Fast Ethernet 
 
backplane enabled.
 
To ensure that the Management Module can see and configure new 
 
Switch 1005 modules correctly when they are inserted, you must insert 
 
them when the MSH chassis and Management Module are powered on.