Configuration / diagnostics using remote mechanisms
6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI)
SCALANCE X-200
Operating Instructions, 12/2011, A5E00349864-19
Operating Instructions, 12/2011, A5E00349864-19
239
As an alternative, you can also display the private MIB directly in the Web browser. Follow
the steps below to display the private MIB:
Start and Internet browser (for example Internet Explorer) and enter the following URL.
Start and Internet browser (for example Internet Explorer) and enter the following URL.
When entering the URL, keep to the upper/lower case notation in the file name.
http://<IP address of the SCALANCE X200>/snScalanceX200.mib
If you have not yet logged on, a login window appears.
Once you are logged on, you have access to the private MIB file of the device.
In the Internet Explorer, select the
View -> Source
menu. With other browsers, select a
comparable menu to display the source code.
If you use the Internet Explorer with the default settings, the private MIB file is opened in a
Notepad editor and can be saved as a text file. The private MIB file also contains a
description of the individual objects.
6.3.6.2
MIB variables
MIB variables of an IE Switch X-200
Key variables in the MIB-II standard
The following section lists certain SNMP variables from MIB II for monitoring the device
status. MIB II describes all the SNMP variables that are usually supported by all SNMP-
compliant devices.
Table 6- 36 Variables in the System directory
Variable
Access rights
Description
sysDescr
Read only
A string with up to 255 characters is used. This value contains the
manufacturer's device ID.
sysObjectID
Read only
The address (object identifier) used to access device-specific SNMP
variables is output here: 1.3.6.1.4.1.4196.1.1.5.2.nnn.mmm
sysUpTime
Read only
Time since the last reset (for example, after power up). The value is
shown in hundredths of a second.
sysContact
Read and write
A contact person can be entered here. (Default: empty string). Possible
value: string with a maximum of 255 characters.
sysName
Read and write
A name for the device can be entered here. (Default: empty string).
Possible value: string with a maximum of 255 characters
sysLocation
Read and write
The device location can be entered here (default: empty string). Possible
value: string with a maximum of 255 characters.
sysService
Read only
Shows the functions (services) provided by the component according to
the ISO/OSI model. Layer functionality:
1. Physical (e.g. repeaters)
2. datalink/subnetwork (e.g. bridges , switches)
2. datalink/subnetwork (e.g. bridges , switches)
3. Internet (e.g. IP gateways, routers)
4. End to end (e.g. IP hosts) 7. Applications (e.g. E-Mail servers)
Data type: 32-bit integer