Configuration / diagnostics using remote mechanisms 
 
6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI) 
SCALANCE X-200 
Operating Instructions, 12/2011, A5E00349864-19 
239
 
As an alternative, you can also display the private MIB directly in the Web browser. Follow 
the steps below to display the private MIB: 
Start and Internet browser (for example Internet Explorer) and enter the following URL. 
When entering the URL, keep to the upper/lower case notation in the file name. 
 
http://<IP address of the SCALANCE X200>/snScalanceX200.mib 
 
If you have not yet logged on, a login window appears. 
Once you are logged on, you have access to the private MIB file of the device. 
In the Internet Explorer, select the 
View -> Source
 menu. With other browsers, select a 
comparable menu to display the source code. 
If you use the Internet Explorer with the default settings, the private MIB file is opened in a 
Notepad editor and can be saved as a text file. The private MIB file also contains a 
description of the individual objects. 
6.3.6.2 
MIB variables 
MIB variables of an IE Switch X-200 
Key variables in the MIB-II standard 
The following section lists certain SNMP variables from MIB II for monitoring the device 
status. MIB II describes all the SNMP variables that are usually supported by all SNMP-
compliant devices. 
Table 6- 36  Variables in the System directory 
Variable 
Access rights 
Description 
sysDescr 
Read only 
A string with up to 255 characters is used. This value contains the 
manufacturer's device ID. 
sysObjectID 
Read only 
The address (object identifier) used to access device-specific SNMP 
variables is output here: 1.3.6.1.4.1.4196.1.1.5.2.nnn.mmm 
sysUpTime 
Read only 
Time since the last reset (for example, after power up). The value is 
shown in hundredths of a second. 
sysContact 
Read and write 
A contact person can be entered here. (Default: empty string). Possible 
value: string with a maximum of 255 characters. 
sysName 
Read and write 
A name for the device can be entered here. (Default: empty string). 
Possible value: string with a maximum of 255 characters 
sysLocation 
Read and write 
The device location can be entered here (default: empty string). Possible 
value: string with a maximum of 255 characters. 
sysService 
Read only 
Shows the functions (services) provided by the component according to 
the ISO/OSI model. Layer functionality: 
1. Physical (e.g. repeaters)  
2. datalink/subnetwork (e.g. bridges , switches) 
3. Internet (e.g. IP gateways, routers)  
4. End to end (e.g. IP hosts) 7. Applications (e.g. E-Mail servers)  
Data type: 32-bit integer