Step 2.  Remove retaining screws placed on top for the 6KPM and Face Plate 
 
On the top of the daughter module there are six 
retaining screws for each 6KPM card. These 
screws are used to secure a 6KPM card in 
position (see Figure 3.5.3a). Remove the three 
standoffs holding the Granddaughter board with 
the chassis. The screen faceplate screws out from 
the inside front of the chassis cover by loosening 
the 4 screws and bracket while holding it down 
firmly.                           Figure 3.5.3a: Top View 
- 6 retaining screws shown by arrows 
 
Step 3.  Remove 6KPM Card 
Carefully and gently pull out the daughter board from the latching connectors, using both 
hands,  gripping the board near the latch-up connectors  as shown in Fig. 3.5.3b .  If the 
now empty slot is to remain unused, be sure to install a 6KPM-BLNK face plate cover.                   
 
Figure 3.5.3b:  
Removing a 
6KPM Card  
 
 
 
 
 
Follow the step 8 to complete the process successfully.  
NOTE:1. If the modular slot has not being used and moved to other unit, the empty 
slot must be covered with Blank cover, to maintain proper air-inflow inside the unit 
and keep off from dust and other unavoidable substance, otherwise can cause a failure 
in the Switch. 
2. If the PM module in the modular slot is not being installed properly or loose in 
connection, the MNS-6K management software will not boot-up properly and a error 
will generate as –{ failed to read register device type (offset 0x1600) on slot “A or B or 
C or D”}, whichever the slot has been used. 
3. Always boot-up the Switch after any new module installation on modular slot to 
confirm the successful installation, before placing the chassis cover.