Magnum 6K16V Managed Fiber Switch         Installation and User Guide (06/04)
 
to the unit. 
 
Power supply options are available to suit the 6K16V Switches to special high-
availability communications and/or heavy industrial-grade applications, including: 
   *    -48VDC, 24VDC and 125VDC with single DC input, 
   *    -48VDC, 24VDC and 125VDC with dual-source DC input, 
See the Appendices of this manual for more details.  Use an RFQ for other variations.  
 
3.5    Alarm Contacts for monitoring internal power, and Software Traps  
The Alarm Contacts feature, standard on Magnum 6K16V’s, provides two 
Form C Normally Closed (NC) contacts to which the user can attach two sets of status 
monitoring wires at the green terminal block. When this option is present, the terminal 
block for Alarm Contacts is part of the Power Input panel in the Magnum 6K16’s case. 
The AC or DC power input connection is in the same panel. A manual On-Off Switch for 
power to the unit is not available on 6K16 units with the Alarm Contacts option, as these 
two features occupy the same space in the case. 
The first NC Alarm Contact (top position) is a “Software Alarm”, operated 
by user settings in the MNS-6K software.  The user can disable the Software Alarm 
feature with a software configuration command if desired. When the Software Alarm is 
enabled, the Form C Normally Closed (NC) contact is held close during normal software 
operation. A user-defined software malfunction, such as an SNMP Trap or a Software 
Security violation or an S-Ring Fault, causes the contact to open and thus trigger an 
alarm in the user’s monitoring system 
The second (bottom position) NC Alarm Contact is held close when there is 
power on the main board inside of the 6K16.  This provides a “Hardware Alarm” because 
the NC contacts will open when internal power is lost, either from an external power 
down condition or by the failure of the power supply inside of the Magnum 6K16 
Switch. Useful info. about Alarm contacts:  
1. There is four terminal block (1,2,3,4)provided next to AC/DC power supply  
2. The top two pins (1,2) are software operated 
3. The bottom two pins (3,4) are hardware     operated 
4. By default it is NC (normally closed) 
5. The software operation need to be enable 
and set to get the Alarm traps. For detail 
information about the Software Alarm and 
software control of SNMP alarm traps, please 
reference the Magnum MNS-6K Software 
User Manual. (Chapter 19th). 
The Alarm Contacts are on the 
front left area (next to the DC power source) 
of the Magnum 6K16V unit and is green in 
color as shown in the picture. 
Relay Contacts
 
 
 
 
24