Magnum 6K16V Managed Fiber Switch         Installation and User Guide (06/04)
 
APPENDIX B : Internal DC Power Supply Options 
 
B1.0 
SPECIFICATIONS FOR MAGNUM 6K16V SWITCHES, DC POWER 
 
 
Power Magnum 6K16V models, for –48V and 24V DC & 125VDC  and 5V 
Power input 
 
Each Magnum Model 6K16V Managed Switch (DC option) requires a DC power 
source, from  for 24VDC,  -48VDC and  125VDC option or 5VDC input. The wide range 
of power input qualifies this product for use in 24VDC, -48VDC as well as 125VDC or 
5VDC environments. The 24VDC, -48VDC or 125VDC or 5VDC power input provides 
an Ethernet networking product utilizing a special type of power supply with a proven 
high-reliability record to fulfill the DC requirement. 
DC Power Terminals: “+”, “
-
internally floating 
GND:  Terminal for “earth” or ground wire connection to the 6K16V chassis 
 
Input Voltage
: 18 to 36 VDC  (24VDC) 
Input current: 1.2Amps max.(for all RJ-45 ports) 
Input current: 2.4Amps max.(for all Fiber ports) 
  
Input Voltage
: -36 to -70 VDC  (-48VDC) 
Input current: 0.8Amps max.(for all RJ-45 ports) 
Input current: 1.2Amps max.(for all Fiber ports) 
 
Input Voltage
: 115 to 150 VDC  (125VDC) 
Input current: 0.3Amps max.(for all RJ-45 ports) 
Input current: 0.35Amps max.(for all Fiber ports)  
Power Consumption: 50 watts max., for fully loaded (fiber ports) 
(24V, -48V, 125V)DC   30 watts typical for all (RJ-45 Ports) 
 
Input Voltage
:  5VDC (+) or (-)  5% (5VDC) 
Input current: 3.5Amps max.(for all RJ-45 ports) 
Input current: 8.0Amps max.(for all Fiber ports) 
Power Consumption: 20 watts max., for fully loaded (fiber ports) 
 
   
    17 watts typical for all (RJ-45 Ports) 
 
B2.0 
-48VDC, 24VDC and 125VDC POWER, THEORY OF OPERATION  
 
The -48VDC, 24VDC and 
125VDC power options are designed 
using diodes inside on each DC power 
input line behind the two external power 
connection terminals, so that the power 
from an external source can only flow 
into the hub. This allows the Switch to operate only whenever DC power is correctly 
A+
A-
GND
GND
CHASSIS
FUSE
+
-
SUPPLY
HUB
POWER  SWITCH
 
 
51