GarrettCom ES42 Manual De Usuario

Descargar
Página de 77
ES42 Series Edge Switches 
 Installation and User Guide (05/05)  
3.8.5 Power 
Budget 
Calculations for ES42 Series, Fiber Media 
 
 
Receiver Sensitivity and Transmitter Power are the parameters necessary to 
compute the power budget. To calculate the power budget of different fiber media 
installations using Magnum products, the following equations should be used: 
OPB (Optical Power Budget) = P
T
(min) - P
R
(min) 
          
 where P
 = Transmitter Output Power, and P
R
 =  Receiver Sensitivity 
 
     Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss) 
     Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km] 
where the “Cable Loss” for 62.5/125 and 50/125
µm
 (m.m.) is 2.8 dB/km,   
 
and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km, 
 
and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km 
 
and the “Cable Loss” for 9/125 (Single-mode) is 0.25 dB/km (SSCX) 
The following data has been collected from component manufacturer’s (Agilent’s, JDS-
Uniphase, stratus, Lucents’) web sites and catalogs to provide guidance to network 
integrators and installers- 
 
53 
www  GarrettCom  com
.
.