Magnum 6K25e Gigabit Fiber Switch            Installation and User Guide (10/07) 
 
21 
www  GarrettCom  com
.
.
The Dual Giga option on each of the two slot add 4 Gigaport to handle the bandwidth 
requirement and 16 10/100 RJ-45 ports to feed the other needs of equipment connected to 
the 6K25e. The robust Tag based vlan feature will able to segregates different ports 
belong to one group and provide an effective solution for bandwidth. The SNMP option 
and secure web based will allow the remote capability and monitoring the network 
securely. The versatile mechanical design with rack mounting capability and AC/DC 
option will be an additional feature to take care of temperature and power option issue. 
 
 
Equipped with IGMP-L2 mode enhanced features allow the Magnum 6K25e to 
meet the fastest growing application of video monitoring or video surveillance 
demand of industry and provide an economical and effective solution to meet 
that expectation. 
 
3.0  
Installation 
Before installing the equipment, it is necessary to take the 
following precautions: 
1.) 
If the equipment is mounted in an enclosed or multiple rack 
assembly, the environmental temperature around the equipment 
must be less than or equal to 50
0
C. 
2.) 
If the equipment is mounted in an enclosed or multiple rack 
assembly, adequate airflow must be maintained for proper and 
safe operation. 
3.) 
If the equipment is mounted in an enclosed or multiple rack 
system, placement of the equipment must not overload or load 
unevenly the rack system. 
4.) 
If the equipment is mounted in an enclosed or multiple rack 
assembly, verify the equipment’s power requirements to prevent 
overloading of the building/s electrical circuits. 
5.)  
If the equipment is mounted in an enclosed or multiple rack 
assembly verify that the equipment has a reliable and 
uncompromised earthing path.
 
6.)  
24vdc, -48vdc, and 125vdc must be installed in restricted 
access locations.
 
7.)  
CB-Circuit breakers of 10Amps should be shown on top of the 
Rack.
 
 
 
 
This section describes installation of the 
Magnum 6K25e Switches, as well as connection of 
the various Ethernet media types. 
 
3.1 
Locating Magnum 6K25e Switches 
 
The location of a Magnum 6K25e Switch 
is dependent on the physical layout of the network.  
Typically the Switch is placed in a central wiring 
location where groups of network devices need to 
be connected in order to communicate with each 
other. These Switches are typically rack mounted in 
a wiring closet see Section 3.3.2 below), but 
because they have rubber feet they can also be installed on a shelf or table top unit. The 
compact size allows it to be easily placed in an office or lab area, and it can also be either 
shelf of wall-mounted (see Section 3.3.1 below). Figure 3.1:  Location of the Magnum 
6K25e’s cooling fans