GarrettCom 6K25e Manual De Usuario

Descargar
Página de 69
Magnum 6K25e Gigabit Fiber Switch            Installation and User Guide (10/07) 
 
22 
www  GarrettCom  com
.
.
 
Locate an AC receptacle that is within six feet (2 meters) of the intended 
Magnum 6K25e site.  The rugged metal case of the Magnum 6K25e will normally 
protect it from accidental damage in a lab or workplace setting.  Maintain an open view 
of the front to visually monitor the status LEDs.  Keep an open area around the unit so 
that cooling can occur from the small fan on the left side, while the unit is in operation. 
See figure below. 
                                
 
3.2 
Connecting Ethernet Media 
 
 
The Magnum 6K25e Switches are specifically designed to support all 
standard Ethernet media types within a single Switch unit.  This is 
accomplished by using a family of different port Modules which can be 
individually selected and configured per-port.  See Section 2.4 for a description 
of the PMs. 
The various media types supported along with the corresponding IEEE 
802.3 and 802.3u standards and connector types are as follows: 
IEEE Standard        Media Type            Max. Distance       Port Module 
   Fiber:
  
 100BASE-FX 
m
m
1
 
Fiber
 
220m  ( ft)
 GBIC-SXSC 
 
 
 
 
sgl.m
2
 
Fiber 5Km   
GBIC-LXSC 
 100BASE-FX 
m
m
1
 
Fiber
 
2.0km  (6,562 ft)
 6K6-MSC, 
-MST 
 
 
 
 
sgl.m
2
 
Fiber 
18.0km (95K ft) 
SSC, SSCL 
 
 
  small form factor   
m
m
1
 
Fiber
 
2.0km  (6,562 ft)
 6K8-MTRJ, 
-MLC
 
 
 
  small form factor   
sgl.
m
1
 
Fiber
 
15 km
 
        6KP8- SLC
 
 
 
   Copper:
 
 
10BASE-T and 100BASE-TX twisted pair 
100m (328 ft) 
6K8-RJ45 
 
 
 
 
 
 
 
1
 mm = multi-mode  
2
 sgl.m = single-mode 
3.2.1 
Connecting Fiber Optic  ST-type, “twist-lock” 
  
 
The following procedure applies to installations using a PM with ST-type fiber 
connectors. This procedure applies to ports using a 6K25e module, MST-type 
port. 
1. 
Before connecting the fiber optic cable, remove the protective dust caps from the
 
tips of the connectors on the PM.  Save these dust caps for future use. 
 
2. 
Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens tissue 
dampened in alcohol.  Make certain the connectors are clean before connecting. 
Note: 
One strand of the duplex fiber optic cable is coded using color 
bands at regular intervals; you must use the color-coded strand on the 
associated ports at each end of the fiber optic segment
.