Magnum 6KQ Managed Field Switch Installation and User Guide             (04/07) 
 
 
20
www  GarrettCom  com
.
.
For DC power input data, see Appendix B.  For Dual Source, see Appendix C 
 
  The rugged metal case of the Magnum 6KQ will normally protect it from 
accidental damage in a lab or workplace setting.  Maintain an open view of the front to 
visually monitor the status LEDs.  Keep an open area around the unit so that cooling can 
occur from convection while the unit is in operation. The 6KQ has no fans, so it is silent 
when in operation.  Internal electronics use the case as a heat sink, so the unit may 
normally be quite warm to the touch. 
                               
3.2 
Connecting Ethernet Media 
 
The Magnum 6KQ Switches are specifically designed to support all standard 
Ethernet media types within a single Switch unit.  This is accomplished by using a family 
of different Port Modules which can be individually selected and configured per-slot.  
See Section 2.2 for a description of the PMs. 
 
The various media types supported along with the corresponding IEEE 802.3, 
802.3D, 802.3u, 802.3AB and 802.3z standards and connector types are as follows: 
 
 
IEEE Standard        Media Type            Max. Distance       Port Module 
   Fiber:
  
 100BASE-FX 
m
m
1
 
Fiber
 
220m  ( ft)
  
GBIC-SXSC 
 
 
 
 
sgl.m
2
 
Fiber 5Km   
GBIC-LXSC 
 100BASE-FX 
m
m
1
 
Fiber
 
2.0km  (6,562 ft)
 6K4-MSC, 
-MST 
 
 
 
 
sgl.m
2
 
Fiber 
18.0km (95K ft) 
SSC, SSCL 
 
 
  small form factor   
m
m
1
 
Fiber
 
2.0km  (6,562 ft)
 6KQ-MTRJ, 
-MLC
 
 
 
  small form factor   
sgl.
m
1
 
Fiber
 
15 km
 
        6KP4V- SLC 
   Copper:
 
 
10BASE-T and 100BASE-TX twisted pair100m (328 ft) 
6KQ-RJ45 
 
1000BASE-TX twisted pair 
 
100m (328 ft) 
GBIC-TP
 
 
 
 
1
 mm = multi-mode  
2
 sgl.m = single-mode 
 
3.2.1 
Connecting Fiber Optic ST-type, “twist-lock” 
  
 
The following procedure applies to installations using a PM with ST-type fiber 
connectors. This procedure applies to ports using a 6KQ module, MST-type port. 
1. 
Before connecting the fiber optic cable, remove the protective dust caps from 
the tips of the connectors on the PM.  Save these dust caps for future use.