GarrettCom P80C Manual De Usuario

Descargar
Página de 28
Magnum P80F & P80C Personal Switches                      Installation and User Guide (07/03)
 
 
 
 
17 
www  GarrettCom  com
.
.
The same procedures as for multi-mode fiber apply to single-mode fiber connectors.  
Follow the steps listed in Section 3.2.2 above. 
 
3.2.5 
Power Budget Calculations for P80F Fiber Media 
 
 
Receiver Sensitivity and Transmitter Power are the parameters necessary to compute 
the power budget. To calculate the power budget of different fiber media installations using 
Magnum products, the following equations should be used: 
OPB (Optical Power Budget) = P
T
(min) - P
R
(min) 
          
 where P
 = Transmitter Output Power, and P
R
 =  Receiver Sensitivity 
 
     Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss) 
     Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km] 
where the “Cable Loss” for 62.5/125 and 50/125
µm
 (m.m.) is 2.8 dB/km,   
 
and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km, 
 
and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km 
 
The following data has been collected from component manufacturer’s (HP’s and Siemens’) web 
sites and catalogs to provide guidance to network designers and installers. 
 
Fiber  
Port 
Module 
Speed, 
 
Std. 
 
Mode
Std. km 
fdx 
(hdx) 
Wave-
length
nm 
Cable 
Size 
µ
X’mitr 
Output 
P
T ,
 dB
R’cvr 
Sens.
P
R ,
dB
Worst 
OPB,
dB 
Worst* 
distance 
Km, fdx
typical 
OPB, 
dB 
typical* 
distance 
Km, fdx  
P80F- 
MST, MSC 
100Mb
FX 
Multi-
mode 
(0.4) 
1300
62.5/125
50/125 
-20 
-23.5 
-31 
-31 
9.0 
5.5 
2.5 
2.0 
14 
12 
4 
P80F-SSC 
100Mb
FX 
Single-
mode 
20 
(0.4) 
1300
9/125 -15 -31 14  28 
17.5  35 
P80F-MTRJ  100Mb
FX 
Multi-
mode 
(0.4) 
1300
62.5/125
50/125 
-20 
-23.5 
-31 
-31 
9.0 
5.5 
3.0 
2.0 
15.8 
12.2 
5.5 
4.0 
Long Reach 
100Mb
FX 
Single-
mode 
40   
(0.4) 
1300
9/125 -5 -34 27  54  32.5  65 
 
* Not
e:  The use of either multi-mode or single-mode fiber to operate at 100Mbps speed over 
long distances (i.e., over approx. 400 meters) can be achieved 
only
 if the following 
factors are both applied: 
• 
The 100Mb fiber segment must operate in full-duplex (FDX) mode, and 
• 
The worst-case OPB of the fiber link must be greater than the fiber cable’s passive 
Attenuation. 
(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor) 
 
3.2.6 
Connections to NICs which support Auto-Negotiation, RJ-45 ports 
 
The copper ports of Magnum P80F and P80C Personal Switches will function properly 
with NICs (Network Interface Cards) which support Auto-Negotiation, and the Fast Link Pulse