HP (Hewlett-Packard) DL160 Manual De Usuario

Descargar
Página de 39
System Unit
Dimensions (H x W x D)
(with bezel)
1.70 x 17.64 x 26.85 in (4.32 x 44.80 x 68.20 cm)
Weight
(approximate)
Maximum
(all hard drives, power
supplies, and processors
installed)
37.00 lb (16.78 kg)
Minimum
(one hard drive, power
supply, and processor
installed)
30.00 lb (13.69 kg)
Input Requirements
(per power supply)
Rated Line Voltage
90 to 140 VAC
180 to 264 VAC
Rated Input Current
7.31A at 115VAC
3.6A at 230VAC
Rated Input Frequency
47 to 63 Hz
Rated Input Power
855W (at 100 VAC),
840.72W (at 200 VAC)
Power Specifications
To review typical system power ratings use the Power Calculator which
is available via the online tool located at URL:
- Click on the system of interest. Example: DL160 G5
- Follow the instructions of the next screens.
Power Supply Output
(per power supply)
Rated Steady-State
Power
653.10W (at 100 VAC),
653.08W (at 200 VAC)
System Inlet
Temperature
Operating
50° to 95° F (10° to 35° C) at sea level with an
altitude derating of 1.8°F per every 1000 ft
(1.0°C per every 305 m) above sea level to a
maximum of 10,000 ft (3050 m), no direct
sustained sunlight. Maximum rate of change
is 18°F/hr (10°C/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if
operating with a fan fault or above 86°F
(30°C).
Non-operating
40° to 140° F (-40° to 60° C)
Maximum rate of change is 36°F/hr (20°C/hr).
Relative Humidity
(non-condensing)
Operating
10% to 85% relative humidity (Rh), 82.4°F
(28°C) maximum wet bulb temperature, non-
condensing.
Non-operating
10% to 95% relative humidity (Rh), 101.7°F
(38.7°C) maximum wet bulb temperature,
non-condensing.
Altitude
Operating
10,000 ft (3050 m). This value may be limited
by the type and number of options installed.
Maximum allowable altitude change rate is
1500 ft/min (457 m/min).
QuickSpecs
HP ProLiant DL160 Generation 5
Technical Specifications
DA - 12902   Worldwide QuickSpecs — Version 19 — 1/26/2009
Page 37