Opticon 25-ULGPMU01-01 Manual De Usuario
Manual No. 25-ULGPMU01-01 Series LGP Handheld CCD Scanner
Redundant Decoding Settings
ZZ
Start/End
Program
Menu
[[
X0
No
redundancy
Y1
X1
Two times
redundant
Y2 %
X2
Three times
redundant
Y3
X3
Four times
redundant
Y!
Redundancy Settings - This is the number of times that a label must be correctly decoded before it is transmitted. Selecting a
higher redundancy count makes reading slower, but it reduces the probability of reading errors, especially when labels of poor
definition are used.
higher redundancy count makes reading slower, but it reduces the probability of reading errors, especially when labels of poor
definition are used.
Positive and Negative Bar Codes
ZZ
Start/End
Program
Menu
[[
V2
Positive
bar codes
W3
V4
Both positive
and negative
bar codes
W5 %
Positive and Negative Bar Codes - Usually bar codes are printed black on white, but sometime white on black. These labels are
called positive and negative, respectively.
Page 57