Manual No. 25-ULGPMU01-01                                                                    Series LGP Handheld CCD Scanner
 
Redundant Decoding Settings 
ZZ 
Start/End 
Program 
Menu 
 [[ 
 
X0 
No 
redundancy 
 Y1 
 
X1 
Two times 
redundant 
 Y2  %
X2 
Three times 
redundant 
 Y3 
 
X3 
Four times 
redundant 
 Y! 
 
Redundancy Settings - This is the number of times that a label must be correctly decoded before it is transmitted. Selecting a 
higher redundancy count makes reading slower, but it reduces the probability of reading errors, especially when labels of poor 
definition are used. 
Positive and Negative Bar Codes 
ZZ 
Start/End 
Program 
Menu 
 [[ 
 
V2 
Positive 
bar codes 
 W3 
 
V4 
Both positive 
and negative 
bar codes 
 W5  %
 
Positive and Negative Bar Codes 
- Usually bar codes are printed black on white, but sometime white on black. These labels are 
called positive and negative, respectively.  
Page 57