Meter Calibration 
66
312776F
8. Dispense component A, B, or Solvent into beaker.
a. To avoid splashing, slowly open sampling 
valves. 
b. For more accurate calibration, adjust the valve 
to dispense at a flow rate similar to your produc-
tion spray flow rate.
c. Dispense a minimum of 250 cc; make sure 
enough material is dispensed to accurately read 
the volume with your beaker. The A and B vol-
umes do not have to be equal or at any particu-
lar ratio.
d. Close sampling valve tightly.
9. The volume that the ProMix measured displays on 
the EasyKey.
10. Compare the amounts on the EasyKey to the 
amount in the beakers.
NOTE: For maximum accuracy, use a gravimetric 
(mass) method to determine the actual volumes dis-
pensed.
11. If the screen and actual volumes are different, enter 
the actual dispensed volume in cc for A, B, or Sol-
vent Volume field, and press the Enter 
 key
If the value was substantially different, repeat the 
calibration process.
NOTE: If the screen and actual volume is the same 
or if for any reason you want to cancel the calibra-
tion procedure, scroll to Abort on the Calibration 
Screen
 men
u and press the Enter 
 key
.
12. After the volume for A, B, or Solvent is entered, the 
ProMix 2KS controller calculates the new flow meter 
K-factor and shows it on the Calibration Screen.
NOTE: K-factor values on the screen are viewable 
only. If needed, you can manually edit the K-factors 
in Advanced Setup Screen 4 (page 36) or Recipe 
Setup Screen 5
 (page 41).
13. Always purge sampling valves after calibrating 
meters. Use one of the following methods. 
Follow  the  Purging Sampling Valves and 
Tubes
 pr
ocedure, page 62.
Place the sampling valve fluid tubes into a com-
patible cleaning fluid (TSL or solvent) or cap 
them.
NOTE: If fluid hardens in sampling tubes, replace 
them with 5/32 in. or 4 mm OD tubing.
14. Make sure both sampling valves are closed and 
both fluid shutoff valves are fully open.
15. Before you begin production, clear the system of 
solvent and prime it with material. 
a. Go to Mix mode.
b. Trigger the gun into a grounded metal pail until 
mixed material flows from the gun nozzle.
c. To begin operation, see Start Up, page 53.