68
312776F
Color Purge/Dump
This sequence flushes out the color with solvent, 
from the color valve to the Dump A valve.
The color change solvent valve and the Dump A 
valve open during the Purge Time.
The color change solvent valve closes when the 
Purge Time expires.
Color Fill
This sequence fills the line with the new color all the 
way to the Dump A valve.
The new color valve and the Dump A valve open 
during the Fill Time.
The new color valve and the Dump A valve close 
when the Fill Time expires.
Catalyst Purge/Dump
This sequence flushes out the catalyst with solvent, 
from the catalyst valve to the Dump B valve.
The catalyst change solvent valve and the Dump B 
valve open during the Purge Time.
The catalyst change solvent valve closes when the 
Purge Time expires.
Catalyst Fill
This sequence fills the line with the new catalyst all 
the way to the Dump B valve.
The new catalyst valve and the Dump B valve open 
during the Fill Time.
The new catalyst valve and the Dump B valve close 
when the Fill Time expires.
First Purge
Select the First Purge Source (air, solvent, or 3rd valve) 
and First Purge Time. For most applications, air is 
selected.
The system purges the old material from the dose 
valves to the gun, using only the selected purge media 
(usually air). The selected purge valve opens during the 
First Purge Time and closes when the time expires.
Chop Cycle
Select the Chop Type (air/solvent or air/3rd valve) and 
Chop Times.
The air purge valve opens only during the air chop 
cycle, and the solvent (or 3rd valve) opens only during 
the solvent chop cycle. The number of chop cycles is 
determined by dividing the Total Chop Time by the sum 
of the Air and Solvent Chop Times.
Final Purge
Select the Final Purge Source (air, solvent, or 3rd valve) 
and Final Purge Time. For most applications, solvent is 
selected.
The system fills the line with solvent from the dose 
valves to the gun, using only the selected purge media 
(usually solvent). The selected purge valve opens 
during the Final Purge Time and closes when the time 
expires.
Fill
This sequence fills the line from the dose valves to the 
gun, and is also referred to as the mixed material fill. 
The system begins mixing components A and B until the 
Fill Time expires.