Setup 
14
313516G
Setup
Connect Air Line
NOTE:
You must install an air pressure regula-
tor (F) on each gun air line to control air 
pressure to the gun. See F
. 6.
If your regulated air source does not 
have a filter, install an air filter (G) on 
each air line to ensure a dry, clean air 
supply to the gun. Dirt and moisture can 
ruin the appearance of your finished 
workpiece. See F
Install a bleed type air shutoff valve (E) 
on each gun air supply line, down-
stream of the gun air regulator, to shut 
off air to the gun.
1. For manifolds with a separate ATOM and 
FAN port, the gun cylinder, fan, and atomi-
zation air must be supplied and regulated 
separately. For the manual fan valve mani-
fold, only one supply line is required for 
both atomization and fan air.
NOTE: The gun atomizing and fan air inlets 
are 3/8 in. O.D. tubing. The cylinder air inlet 
accepts 1/4 in. (6.3 mm) O.D. tubing. Use 3/8 
in. (9.5 mm) O.D. tubing for fan and atomiza-
tion air to minimize excessive pressure drop in 
the hoses.
2. Connect each air hose (D) to a regulated 
air supply line (H).
Connect Fluid Hose
NOTE:
Before connecting the fluid line, blow it 
out with air and flush it with solvent. Use 
solvent that is compatible with the fluid 
to be sprayed.
Install a fluid regulator (L) on the fluid 
line to control fluid pressure to the gun.
Install a fluid shutoff valve (M) to shut off 
the fluid supply to the gun.
Filter the fluid line of coarse particles 
and sediment to avoid clogging the fluid 
nozzle and causing finishing defects. 
Inline fluid filter 24B707 is available. 
See Accessories, pag34.
1. Connect the fluid supply hose (J) to the gun 
fluid inlet (S), 1/4 npsm thread. See F
2. Connect the other end of the fluid hose (J) 
to a regulated fluid supply outlet (M).
3. In a circulating system, connect a 
grounded fluid return hose to the gun fluid 
outlet (T). See F
In a non-circulating system, remove the 
gun fluid outlet fitting (T) and plug the outlet 
port with the pipe plug supplied. See F
. 8.
F
IG
. 6: Connect Air Line
ti01990
H
G
F
E
D
F
IG
. 7: Connect Fluid Hose.
M
L
K
J
ti7016a