Super Finish 7000
GB
r epa Irs  at  the  un It
10.10 
Remedy In cASe OF FAultS
t ype of  malfunc t Ion w ha t  else ?
poss Ible  c a use
measures  for  el ImIn at Ing  the  malfunc t Ion
Unit does not start
Motor switch can not 
switched on 
Indicating lamp does 
not illuminate
No voltage applied
Check voltage supply
Motor switch can not 
switched on 
Indicating lamp illumi-
nates
Unit fuse has triggered
Let the motor cool down 
Unit does not suck in
Air bubbles exit from 
the return hose
Unit is sucking in outside 
air
Check: Suction system tightened properly? 
Inlet valve button leaky? -> Replace wiper and 
O-ring (-> refer to Section 10.1)
Air bubbles do not exit 
at the return hose
Inlet valve clogged
Press the inlet valve button until the stop is 
reached several times by hand
Inlet/outlet valve soiled 
/ foreign bodies (e.g. 
threads) drawn in / worn
Remove the valves and clean then (-> refer to 
Section Pkt.10.2/10.3) / replace worn parts 
Pressure control valve 
turned down completely
Turn the pressure control valve to the right un-
til the stop is reached
Unit does not gener-
ate pressure
Unit has sucked in
Air in the oil circuit
Bleed the oil circuit in the unit by turning the 
pressure control valve completely to the left 
(until overturning) and let it run approx. 2 – 3 
min. Then turn the pressure control valve to 
the right and set the spraying pressure (repeat 
process several times, if necessary). 
Unit reached pres-
sure, but the pressure 
collapses, also at the 
pressure gage, during 
spraying.
Suction filter clogged
Check the suction filter. If necessary, clean/
replace
Paint cannot be worked in 
this state. Due to its prop-
erties the paint clogs the 
valves (inlet valve) and the 
delivery rate is too low.
Dilute the paint
Unit reached pressure, 
but the pressure col-
lapses during spraying. 
pressure gauge still 
shows high pressure
Clogged filter do not let 
enough paint pass
Check/clean the (high-pressure filter) gun filter
Tip clogged
Clean the tip (-> refer to Section 8.4)
Unit does not generate 
the max. pressure pos-
sible. Paint neverthe-
less exits at the return 
hose. 
Relief valve defective
Clean or replace the relief valve (-> refer to 
Section 10.5)
Poor spray pattern
Tip clogged
Clean the tip (-> refer to Section 8.4)
Incorrect nozzle size
Use different nozzle size
During multiple-gun 
operation
Too many guns con-
nected
Use fewer guns