Graco 3A0732J Manual De Usuario

Descargar
Página de 44
Operation
3A0732J
11
2.
See F
. 2. Close gun air regulator (E) and pump air 
regulator (F) by turning knobs counterclockwise 
reducing pressure to zero. Close bleed-type air 
valve (D). 
3.
Connect air line to bleed type air valve.
4.
Check that all fittings throughout system are tight-
ened securely.
5.
Position pail close to pump. Suction hose is 3 ft 
(0.9 m) long. Do not stretch hose tight; let it hang to 
assist fluid flow into pump.
6.
Hold metal part of gun firmly to side of grounded 
metal pail, unlock trigger, and hold trigger open.
7.
Open bleed-type air valve. Slowly turn pump air reg-
ulator clockwise, increasing pressure until pump 
starts.
8.
Cycle pump slowly until all air is pushed out and 
pump and hoses are fully primed.
9.
Release gun trigger and lock trigger safety. Pump 
should stall against pressure.
Install the Spray Tip
Follow Pressure Relief Procedure, page 10. Install the 
spray tip and tip guard as explained in your separate 
gun manual, supplied.
The fluid output and pattern width depend on the size of 
the spray tip, the fluid viscosity, and the fluid pressure. 
Use the Spray Tip Selection Chart in your gun instruc-
tion manual as a guide for selecting an appropriate 
spray tip for your application. 
NOTE: The maximum recommended spray tip size is 
.019 in. (0.483 mm).
Adjust the Atomization
NOTE: Use this procedure with airless and air-assisted 
spray guns.
1.
Do not turn on atomizing air supply. Fluid pressure 
is controlled by the air pressure supplied to the 
pump (pump air regulator). Set fluid pressure at low 
starting pressure. For low viscosity fluids (less than 
25 sec, #2 Zahn cup) with lower percent solids (typi-
cally less than 40%), start at 300 psi (2.1 MPa, 21 
bar) at pump outlet. For fluids with higher viscosity 
or higher solids content, start at 600 psi (4.2 MPa, 
42 bar). Refer to the following example.
Example:
2.
Hold gun perpendicular and approximately 12 
inches (304 mm) from surface.
3.
Move gun first, then pull gun trigger to spray onto 
test paper.
4.
Increase fluid pressure in 100 psi (0.7 MPa, 7 bar) 
increments, just to the point where a further 
increase in fluid pressure does not significantly 
improve fluid atomization. Refer to the following 
example.
Example:
5.
If you are using an air-assisted spray gun, see 
Adjust the Spray Pattern on page 12.
Pump 
Ratio
Pump Air 
Regulator Setting
psi (MPa, bar)
Approximate 
Fluid Pressure
psig (MPa, bar)
15:1
x
20 (0.14, 1.4)
=
300 (2.1, 21)
30:1
x
20 (0.14, 1.4)
=
600 (4.2, 42)
Pump 
Ratio
Pump Air Regulator 
Increment
psi (MPa, bar)
Incremental 
Fluid Pressure
psi (MPa, bar)
15:1
x
7 (.05, 0.5)
=
100 (0.7, 7.0)
30:1
x
3.3 (0.02, 0.2)
=
100 (0.7, 7.0)