Maintenance
3A0732J
13
Maintenance
Tighten Threaded Connections
Before each use, check all hoses for wear or damage. 
Replace as necessary. Check that all threaded connec-
tions are tight and leak-free.
Flush the Pump
Flush the pump:
Before first use
When changing colors or fluids
Before repairing equipment
Before fluid dries or settles out in a dormant pump 
(check the pot life of catalyzed fluids)
At the end of the day
Before storing the pump.
Flush at the lowest pressure possible. Flush with a fluid 
that is compatible with the fluid you are pumping and 
with the wetted parts in your system. Check with your 
fluid manufacturer or supplier for recommended flushing 
fluids and flushing frequency.
1.
2.
Remove tip guard and spray tip from gun. Refer to 
separate gun manual.
3.
Place suction tube in grounded metal pail containing 
cleaning fluid.
4.
Set pump to lowest possible fluid pressure, and start 
pump.
5.
Hold a metal part of the gun firmly to a grounded 
metal pail. 
6.
Trigger gun. Flush system until clear solvent flows 
from gun.
7.
8.
Clean the tip guard, spray tip, and fluid filter element 
separately, then reinstall them.
9.
Clean inside and outside of suction tube and suction 
hose.
Read all Warnings. Follow all Grounding instruc-
tions. See page 8.