Wilton 15S Manual De Usuario

Descargar
Página de 40
 
22
Method 2 uses a scrap board and calipers. 
1.  Turn on the digital display. It turns on in 
absolute mode. 
2.  Plane one side of a scrap board at an 
appropriate and safe cutting depth (1/16” for 
example). 
3.  Raise the table by the same amount (1/16”), 
then turn the board over and plane the other 
side. Do not move the table from the current 
position. 
4.  Measure the planed board carefully with 
calipers. (Our example in Fig. 42 shows the 
calipers reading .850”). This measurement 
of the finished board is the equivalent of the 
distance from table to knife. 
5.  Input the measurement on the calipers into 
the digital display. Refer to the instructions 
above involving the SET button function to 
input this number into your digital display. 
(Figure 42 shows the .850” measurement 
now set in the digital display.) 
 
Figure 42 
Using Relative Measurement Mode 
The absolute setting, for which you should have 
already established the zero point, gives the 
width of your finished board after cutting 
(distance from table to cutterhead).  
The relative measurement mode is useful for 
measuring only the amount of stock that you 
wish to remove (i.e., depth of cut), and 
eliminates having to add or subtract to find the 
proper setting. It is especially helpful when 
planing many boards to the same thickness. 
Here is an example using relative measurement:  
1.  You have planed a board at a setting of one 
inch at absolute measurement. Do not move 
the table from this position. You wish to 
increase the depth of cut on the next run by 
.063 inches.  
2. Press ABS button to start relative 
measurement mode (“INC” will appear on 
the display). 
3.  Follow the previous instructions on using the 
SET button function. You would input zeros 
for all digits, thus establishing zero setting 
for relative measurement mode. 
4.  After setting relative zero, bring the table up 
until the digital display reads “.065” inches in 
relative measurement mode. You can now 
plane your board with exact results. Of 
course, you can now toggle back and forth 
between relative and absolute mode (by 
pressing ABS button) and get both stock 
thickness and depth of cut readings at the 
same time. 
 
Clearing a Jammed Board
 
If you have to temporarily move the planer table 
(for example, to clear a jammed board) use the 
HOLD button to remember your original setting.  
1.  If a board jams, press the HOLD button. 
Your setting will be “frozen” on the display. 
2.  Lower the table and clear the jam. 
3.  Raise the table back up to the general 
location, and make a mental note of the 
number “frozen” on the display. 
4.  Press HOLD to return the display back to 
absolute measurement, and adjust the table 
until it matches the measurement previously 
frozen on the display.  
NOTE: The HOLD button will not permanently 
save a setting. When the button is pressed a 
second time, the number disappears. 
More Uses
 
The digital scale has been designed to save the 
operator time and energy, leading to increased 
productivity. As you become proficient with the 
use of the digital readout and explore how to use 
one function in conjunction with another, you’ll 
be able to tailor its functions to suit your own 
work habits and planing needs.