20
Functions of the Digital 
Scale 
(Model 15S only)
 
Figure 40 identifies the parts of the digital scale. 
The button functions are discussed below, 
followed by a section giving practical examples 
of how to calibrate your settings, and how these 
functions can be used for daily planer 
operations. 
Before using the device, wipe down the vertical 
scale with a dry, soft cloth. Do not use cleaning 
solutions. Do not allow any liquids (such as 
machine oil) to contact the body of the digital 
display. Keep the device clean. 
Data from the digital scale can be input into a 
computer via the port at the side of the device. 
Simply slide off the small port cover (see Fig. 
40). 
This device uses a 1.55 volt battery cell (SR44). 
If it needs replacing (see Troubleshooting on 
page 26 to determine this) slide off the battery 
cover and insert the battery, with the positive 
pole of the battery facing out. NOTE: After 
replacing a battery, the digital display setting 
defaults to zero and must be recalibrated. 
 
ON/OFF/ZERO – power and zero-setting 
Press ON/OFF/ZERO button no longer than 3 
seconds to power on. 
Press ON/OFF/ZERO button at least 3 seconds 
to shut off the digital display. 
While in relative mode, press ON/OFF/ZERO 
(no longer than 3 seconds) to set current 
position as relative zero point. 
While in absolute mode, press ON/OFF/ZERO 
(no longer than 3 seconds) to set current 
position as absolute zero point. 
 
ABS – relative/absolute modes 
The device is in absolute mode as soon as 
power is turned on, and displays absolute zero. 
Moving the planer table up and down begins 
absolute measurement. Absolute measurement 
is set based upon the distance from cutterhead 
to table, and thus represents the thickness of 
your board.  
Press ABS button (no longer than 3 seconds) to 
switch to relative mode. “INC” will appear on the 
display. The value shown is in relative mode; it 
is an incremental position that can be zeroed at 
any point and determines not the thickness of a 
board, but how much material will be removed 
from a board. Moving the table up and down will 
now display relative measurement until you 
press ABS again to go back to absolute. 
IMPORTANT: Always place the digital display in 
relative (“INC”) mode before turning it off. If you 
turn it off while in absolute (“ABS”) mode, your 
absolute setting will default to zero. 
 
Figure 40 
MM/INCH – millimeters/inches 
Pressing this button toggles back and forth 
between standard and metric, and can be done 
at any time without affecting saved settings. 
 
HOLD – maintains data on the display. 
Press this button to “freeze” a measurement on 
the display; it will remain even if the table is 
moved. Press HOLD again and it returns to 
normal measurements. 
 
SET – preset a value 
Press SET; the indicator will flash “SET”. Press 
and hold the SET button and each digit flashes 
in turn. When the digit you want flashes, release 
the SET button. Press SET button once (no 
longer than 1 second) and that digit will increase 
by one each time SET is pressed. When 
finished, press and hold SET button until 
indicator “SET” flashes, then press SET again 
(no longer than 1 second). The indicator “SET” 
disappears and the value you just input is 
displayed on the screen.