Signal Routing
Measurement Operations & Settings
Agilent 8163A/B, 8164A/B & 8166A/B Mainframes, Fifth Edition
169
Signal Routing
The commands in this section allow you to control Agilent 8159x Optical 
Switch modules
command:
:ROUTe[n][:CHANnel[m]]
syntax:
:ROUTe[n]:[CHANnel[m]]<wsp><channel_list>
description:
Sets the channel route between two ports.
N O T E
When you use switches with dependent connections (e.g. the 2x2 switch), it is possible that 
one route configuration automatically changes another connection!
parameters:
n:
m:
channel_list
the slot number of the switch module
the switch channel within the selected switch module. 
e.g. for dual 1 x 2 module m = 1 for switch 1; m = 2 for switch 2
the route between left and right ports. 
channel_list format: [A....Z],[1....n]
response:
If an invalid route is selected the following error message is returned - "StatParamError"
example:
rout3:chan1 A,2     (module in slot 3,channel 1, connect port A with port 2)
affects:
All switch modules
command:
:ROUTe[n][:CHANnel[m]]?
syntax:
:ROUTe[n]:[CHANnel[m]]<wsp><channel_list>
description:
Queries the current channel route of the switch for a specific module and switch channel.
parameters:
n:
m:
the slot number of the switch module
the switch channel within the selected switch module. Default value is 1.
response:
 [A.....Z],[1.....n];[A.....Z],[1.....n] as a text string. 
"," separates input and output ports of a specific connection.
";" separates parallel connections (as used in 2x2 switch).
example:
rout3:chan1? 
→ A,1 simple 1xN switch
rout2:chan1? 
→ A,2;B,1  (2x2 crossover switch in crossover config).
affects: