Smeg GKC755 Manual De Usuario

Descargar
Página de 18
 
Instructions for the installer
 
 
31 
 
 
5.3 
Regulation for natural gas 
 
   
 
 
The hob has been inspected for G25 (2L 3B/P) at a pressure of 25 
mbar. To allow the unit to work with this type of gas, perform the same
operations described in paragraph “5.2 Regulation for LPG”, but choose 
the nozzles and regulate the primary air for natural gas, as shown in the
following table and in paragraph "5.4 Regulation of primary air”. After the 
regulations have been carried out, restore the seals with sealing wax or
equivalent material. 
Burner 
Rated 
heating 
capacity 
G25  25 mbar
 
 
 
Nozzle diameter 
1/100 mm 
Reduced flowrate 
(W) 
Auxiliary 
1.05 
76 
380 
Semirapid 
1.65 
98 
380 
Rapid 
2.7 
123 
650 
Rapid large 
3.1 
130 
750 
Fish pan 
2.15 
110 
750 
Ultra rapid 
3.3 
135 
1200 
Internal 
1.05 
76 
380 
Double 
crown 
External 
3.9 
150 
1200