Instructions for the installer
 
 
 
33 
 
 
6  FINAL OPERATIONS 
 
  
 
 Having carried out the above adjustments, reassemble the appliance 
following, backwards, the instructions in paragraph “5.1 Removing the 
hob”. 
 
  
 
 
6.1 
Regulation of minimum for natural gas 
 
   
 
 Replace the components on the burner and 
slide the knobs on the gas tap pins. Light the 
burner and set it at minimum position. Remove 
the knob and turn the regulation screw inside or 
next to the gas tap pin (depending on the 
model) until you get a suitable minimum flame. 
Replace the knob and check burner flame 
stability: (rapidly turning the knob from 
maximum to minimum position, the flame 
should not go out). 
 
  
 
 
6.2 
Regulation of minimum for LPG 
 
   
 
 To regulate the minimum for LPG, completely tighten (clockwise) the 
screw inside or next to the gas tap pin (depending on the model). 
The diameters of the by-passes for each burner are given in table “5.2
 
Regulation for LPG”. 
 
 
 
After having regulated the device with a gas other than the one tested, 
 
replace the label located on the bottom enclosure with the one that 
corresponds to the new gas. The label is inside the bag that contains 
 
the nozzles.