Electrical connections
The appliance is predisposed to function
with  a  230-240V  monophase  voltage
tension. Connection must be carried out in
conformity  with  the  regulations  and
dispositions of the laws in force.
Before connecting ensure that:
- The limiter valve and the electrical mains
can support the voltage of the appliance
(see registration plate).
- The power supply is correctly earthed
according to the regulations in force.
- The plug or omnipolar interrupter used
can  be  easily  reached  once  the
appliance has been installed.
The appliance is supplied with a supply cord
incorporating a plug. Connect the plug to
an appropriate security socket.
If  a  direct  connection  to  the  mains  is
required,  an  omnipolar  interrupter  with  a
minimum  opening  of  3mm  between
contacts, dimensioned to the voltage and
corresponding to the regulations in force,
should be interposed between the appliance
and  the  supply. The  yellow/green  earth
cable  must  not  be  interrupted  by  the
interrupter.  The  brown  coloured  phase
cable (situated at terminal “L” of the terminal
box)  must  always  be  connected  to  the
network  phase.  The  voltage  cable  must
always be positioned in such a manner that
it at no point reaches a temperature of
50 °C above room temperature. An example
of the best routing is shown in fig. 11.
In case of substitution of the voltage cable
use cable type H05 RRF having a section
suited  to  the  charge,  it  is  furthermore
necessary that the yellow/green earth wire
be  approximately  2cm  longer  than  the
phase and neutral wires (Fig. 10).
After  connection  try  out  the  heating
elements  allowing  them  to  function  for
approximately 3 minutes.
Ground (yellow - green)
Neutral wire
Phase
FO 0480
Fig.10
NO
Gas
pipeline
Electric
wire
The  manufacturer  declines  all
responsibility in case the prevention of
accidents regulations are not respected.
Fig.11
Gas
pipeline
Electric
wire
Gas
pipeline
Electric
wire
YES