REFILL - Range: 20 to 230
 
This  function  allows  the  operator  to  adjust  the 
sensitivity of the refill circuit. This is mainly a trouble-
shooting feature. Water in different geographical loca-
tions can have different conductivities. By adjusting 
the sensitivity of the refill circuit, this will allow the 
brewer to operate under various water conditions.
P2721
Procedure  to  set  the  sensitivity  threshold  of  the 
refill circuit:
NOTE: Make sure the water in the tank is touching 
the refill probe.
1.  Press and hold upper right hidden switch until the 
display reads UNITS. Release switch.  Continue to 
press and release switch until the display reads 
REFILL and shows a number on both sides of the 
word.
2.  To adjust the threshold setting, press (-) to de-
crease, or (+) to increase the setting.
NOTE: Always make sure that the number on the right 
is larger than the number on the left when water is in 
contact with the refill probe in the tank.
3.  When finished, press and release DONE. This saves 
the new setting and advances to the next function 
screen, L SPRY OZ/M. Another alternative is to 
press and release either of the ON/OFF switches 
located on the front switch panel to exit REFILL 
and return to the MAIN SCREEN.
SPRAY OZ/M
  This function allows the operator to view or to enter 
the actual flow rate coming out of the sprayhead. This 
is NOT used to change the actual flow rate, but to tell 
the internal controller how fast the water is flowing. 
The unit of measure is ounces per minute (Oz/M).
P2721
Procedure to set ready temperature:
1.  Press and hold upper right hidden switch until the 
display reads UNITS. Release switch.  Continue to 
press and release switch until the display reads 
SET READY.
2.  To  adjust  the  ready  temperature,  press  the  (-) 
button to decrease, or (+) to increase the ready 
temperature.
3.  When finished, press and release DONE to save 
the new setting, exit the SET READY function and 
advance to the next function screen, REFILL. An-
other alternative is to press and release either of 
the ON/OFF switches located on the front switch 
panel to exit the SET READY function and return 
to the MAIN SCREEN.
2.  To adjust the brew temperature, press (-) to de-
crease or (+) to increase the brew temperature.
3.  When finished, press and release DONE to save 
the new setting, exit the SET TEMP function and 
advance to the next function screen,  SET READY. 
Another alternative is to press and release either of 
the ON/OFF switches located on the front switch 
panel to exit the SET TEMP function and return to 
the MAIN SCREEN.
SET READY - Range: 185˚F (85˚C) to 203˚F (95˚C)
 
This function allows the operator to set the mini-
mum temperature allowable to start a brew cycle. The 
range can be from 185˚F (85˚C) to within 2˚F (-1.7°C) 
of the SET TEMP. The water must be at the SET READY 
temperature or higher for the display to indicate READY 
TO BREW. If brew lockout is enabled, the brewing pro-
cess will not start below this READY temperature.
NOTE: The upper limit for SET READY temperature 
is 2˚F (-1.7°C) less than the water temperature (SET 
TEMP) setting.
SET READY: XXX°
  (-) 
DONE 
(+)
XXX REFILL -> XXX
  (-) 
DONE 
(+)
P2721
L SPRY OZ/M: XXX
  (-) 
DONE 
(+)
SET TEMP (cont.)
PROGRAMMING THE BREWER (cont.)