Procedure to adjust the flow rate setting:
1.  Press and hold upper right hidden switch until the 
display reads UNITS. Release switch.  Continue to 
press and release switch until the display reads 
L SPRY OZ/M. The number represents what the 
brewer thinks is the flow rate of the sprayhead in 
ounces per minute.
2.  If the actual flow rate of the sprayhead is known, 
but is different than the number on the display, 
use the (-) and (+) to enter the correct flow rate 
in ounces per minute.
3.  When finished, press and release DONE.  This saves 
the new setting and advances to R SPRY OZ/M. 
When finished setting the right side, press and 
release DONE to advance to next function screen, 
L BYPS OZ/M. Another alternative is to press and 
release either ON/OFF switch located on the front 
switch panel to exit R SPRY OZ/M function and 
return to the MAIN SCREEN.
BYPASS OZ/M
 
This function allows the operator to view or to enter 
the actual flow rate coming out of the bypass nozzle.  
This is NOT used to change the actual flow rate, but to 
tell the internal controller how fast the water is flowing. 
The unit of measure is ounces per minute.
SPRAY OZ/M (cont.)
P2721
L BYPS OZ/M: XXX
  (-) 
DONE 
(+)
Procedure to adjust the flow rate setting:
1.  Press  and  hold  upper  right  hidden  switch  until 
display  reads  UNITS.  Release  switch.  Continue 
to press and release switch until display reads 
BYPASS OZ/M. The number represents what the 
brewer thinks is the flow rate of the bypass valve 
in ounces per minute.
2.  If the actual flow rate of the bypass valve is known, 
but is different than the number on the display, 
use the (-) and (+) to enter the correct flow rate 
in ounces per minute.
3.  When finished,  press and release the DONE.   This 
saves the new setting and advances to R BYPS 
OZ/M. When finished setting right side, press and 
release DONE to advance to next function screen, 
CALIBRATE FLOW. Another alternative is to press 
and release either ON/OFF switch located on the 
front switch panel to exit the BYPASS OZ/M func-
tion and return to the MAIN SCREEN.
CALIBRATE FLOW
 
This function allows the operator to enter the actual 
flow rate of the sprayhead and the bypass for each 
side of the brewer by dispensing both separately for 
one minute. The volumes are then entered in ounces 
per minute (OZ/M). 
Procedures to calibrate the sprayhead flow rate:
1.  Place a container, accurately graduated in ounces, 
and with a minimum capacity of 60 ounces, be-
neath the funnel on the side of the brewer to be 
calibrated.
2.  Press and hold upper right hidden switch until the 
display  reads  UNITS.  Release  switch.  Continue 
to  press  and  release  switch  until  display  reads 
CALIBRATE FLOW ?.
3.  Press and release YES to advance to the SPRAY 
HEAD CAL? function screen. (Pressing NO in the 
CALIBRATE FLOW screen will advance to the next 
function screen, BREW COUNTERS).
4.  Press and release YES. The display should read 
CONTAINER  READY?  If  the  container  is  under 
the funnel, press YES. The display should read 
CALIBRATE SPRAY .. PRESS BREW TO START.
5.  Press and release the BREW switch on the side to 
be calibrated. The display should read CALIBRATE 
SPRAY .. 60 SEC TO FINISH. The 60 second timer 
on the display will count down to zero. When the 
counter reaches zero, the display will change to 
ENTER  OZ,  along with a number signifying ounces 
per minute.
6.  Measure  the  amount  of  water  in  the  container 
and using the (-) or (+), adjust the amount on the 
display to match the amount in the container. Then 
press DONE.
7.  The display should now read NEW L or R SPRY 
FLOW,  along  with  the  correct  flow  rate  of  the 
sprayhead  in  ounces  per  minute.  After  about  5 
seconds, the display will return to the CALIBRATE 
FLOW screen.
8.  To exit the CALIBRATE FLOW program, press NO 
PROGRAMMING THE BREWER (cont.)
29877-3 062005