TROUBLESHOOTING (cont.)
REMEDY
(A) The circuit breaker must not be 
tripped. 
(B) Refer to Service - Circuit Breaker 
for  testing  procedures.  See  page 
27.
Remove  the  lamps  and  check  for 
continuity across the base and tip. 
Replace if necessary.
Refer to Service - Transformer for 
testing procedures. See page 49. 
Refer to Service - Lamp Holder/Sock-
et Assembly for testing procedures. 
See page 44.
(A) The auger switch must be in the 
“ON” position.
(B) Refer to Service - Auger ON/OFF 
Switch(es)  for  testing  procedures. 
See page 26.
Refer  to  Service  -  Auger  Motor 
Capacitor(s) for testing procedures. 
See page 23.
Refer to Service - Auger Motor(s) for 
testing procedures. See page 22.
Refer to Service - Fan Motor for test-
ing procedures. See page 39.
The fan motor will run for approxi-
mately two minutes after compressor 
shuts off.
PROBABLE CAUSE
3. Circuit Breaker
4. Lamps
5.Transformer
6. Lamp Holder/Socket Assy
1. Auger ON/OFF Switch(es)
2. Auger Motor Capacitor(s)
3. Auger Motor(s)
1. Fan Motor
1. Time Delay
PROBLEM
Hopper  Display  Lights  not  on 
(cont.) 
Auger Motor won’t turn 
Fan not spinning (With adjustment 
Board  L.E.D.s  ON  steadily  for  two 
minutes)
Fan  spins  after  compressor  shuts 
off