Page 20
PROBABLE CAUSE
REMEDY
PROBLEM
TROUBLESHOOTING
Temperature Too Low
Heating Time Too Long
Fill Time Too Long
Temp  Sensor  Out  Of  Range, 
Check For Bad Connections
Temp  Sensor  Out  Of  Range, 
Check Wire For Shorts
Equipment will not operate
Water fl ows into tank continu-
ously with power removed from 
brewer.
1.  Water  temperature  in  the 
tank does not meet the ready 
temperature.
1. Tank Heater failure.
2.  Control  Board/Thermistor 
failure
1. Water shut off to brewer
2. Supply line too small or ob-
structed
3. Inlet Solenoid failure
4. Control Board Failure
5. ON/OFF switch is OFF
1.  Temperature  Sensor  Probe 
wire(s)  broken  or  not  making 
connection
1.  Temperature  Sensor  Probe 
wire(s)  shorted  to  housing  or 
to each other.
1. No power
2. incorrect voltage
1. Refi ll valve
A)  Wait for the brewer to heat 
to the proper temperature.
B)  Disable  the  BREW  LOCK-
OUT function.  See page 12 for 
procedure.
Service required
Service required
Check water supply shut-off
Replace or repair as needed
Service Required
Service Required
Turn switch ON
Service required
Service required
Verify  power  cord  is  plugged 
into outlet.
Service required
Service required