Bunn Axiom Series Manual De Usuario

Descargar
Página de 26
Page 21
PROBABLE CAUSE
REMEDY
PROBLEM
TROUBLESHOOTING (cont.)
Check  plumbing  and  shut-off 
valves
A)  Wait for the brewer to heat 
to the proper temperature
B)  Disable  the  BREW  LOCK-
OUT function.  See page 12 for 
procedure
Turn on
Service required
Service required
Service required
1. No water
2.  Water  temperature  in  the 
tank does not meet the ready 
temperature.
3.  "ENABLE  BREW  ON/OFF" 
switch not on.
4. Brew switch
5. Brew valve
6. Control Board
Brew cycle will not start
Spitting  or  unusual  steaming 
from sprayhead or air vent.
1. Lime buildup
2. Temperature probe
3. Control Board
Refer to page # 8
Service required
Service required
Inconsistent beverage level
Refer to page # 8
Service required
1. Lime buildup
2. Brew valve
Dripping from sprayhead.
Water overfl ows fi lter.
Beverage overfl ows decanter
Service required
BUNN  paper  fi lters  should  be 
used for proper extraction
Replace sprayhead
The brew cycle should be start-
ed only with an empty decanter 
under the funnel.
Adjust  the  brew  volume,  cali-
brate sprayhead as required to 
achieve the desired volume for 
each brew cycle.
1. Brew valve
1. Type of paper fi lter
2. No sprayhead
1. Beverage left in decanter  from 
previous brew
2. Brew volume adjustment
39130 053106