HOT DRINK SETUP/PROGRAMMING GUIDE
6700001
Page - 51
November, 2002
VIEW TIMES NO CUP WAS DETECTED AFTER A CUP
RING CYCLED
         (NOT SHOWN IF ZERO)
1. Press 
, then press 
  until the display shows 
PV.FL1
XX.  XX represents the number of times a cup was not detected after
ring 1 cycled.  Check the cup ring adjustment (see the Operator’s
Guide
), or the cup stack for damage if the count is excessive.
2. Press 
  to clear the count.
3. Press  until the display shows 
PV.FL2 XX.  XX represents the number
of times a cup was not detected after ring 2 cycled.  Check the cup ring
adjustment (see the Operator’s Guide), or the cup stack for damage if
the count is excessive.
4. Continue.
VIEW HOME SWITCH USAGE RELATED TO POSIVEND™
             (NOT SHOWN IF ZERO)
1. Press 
, then press 
  until the display shows 
WO.PV XX.
XX represents the number of times home switches were used due to
OPT’N POSI.V selected but not working.
2. Continue.