HOT DRINK SETUP/PROGRAMMING GUIDE
November, 2002
Page - 52
6700001
VIEW POSIVEND™ LAST RECORDED CALIBRATION
           VALUE
1. Press 
  PosiVend™ until the display shows 
CAL.LST XXX.
XXX can be any number from 0 to 255, and represents the most re-
cent value read from the sensor.  The lower the number the greater
the sensor blockage.  A number of 255 means that there is a fatal
problem with the PosiVend™ interface board.  Ensure the PosiV-
end™ interface PCB is properly connected to the main controller
PCB.
2. Continue.
 VIEW POSIVEND™ AVERAGE CALIBRATION VALUE
1.
Press 
, then press 
  until the display shows
CAL.AVE XXX.  XXX
 represents the average sensor calibration
value (should be between 50 and 255 for proper sensor
operation - i.e. 51 through 254).  Although this number could
go as low as 20, the PosiVend™ system will be inoperative in
this condition.
2. Continue.
CLEAR TANK ERRORS AND FILL THE TANK
1. Press 
, then press 
  until the display shows 
TANK
FILL.
2. Press 
.  This clears any tank error and starts filling the
tank, if necessary.  If it is taking a long time to fill the tank AND
THERE ARE NO LEAKS, you may see
 TANK ERR in the diagnostic
list again.  Just press 
  again after making sure there are no
other problems, such as a restriction in the water inlet line or a
clogged water filter.
3. Continue.