Graco 309572ZAG Manual De Usuario

Descargar
Página de 34
Installation
309572ZAG
21
Connect Hoses to Proportioner
1. Grease with Fusion
®
 grease and connect fluid 
hoses to proportioner fluid manifold (M). Red 
for hardener (ISO), blue for resin (RES). 
NOTE: For proportioners with termination box 
(TB), follow step 2, For proportioners with electrical 
splice connectors (12) follow step 3. 
2. Connect hose power wires to terminal block (C) 
on termination box (TB). Remove box cover (D) 
and loosen lower strain relief (E). Route wires 
through strain relief and fully insert into terminal 
block (A and B hose wire positions are not 
important). Torque terminal connector screws 
(C) to 26-30 in-lb (2.9-3.3 N•m). Fully tighten 
strain relief screws and replace cover.
3. Connect hose power wires to electrical splice 
connectors (12) from proportioner or accessory 
control box. See Connect Heated Hoses
page 14, step 5. Connect FTS hose cable (4) to 
cable from proportioner or accessory control 
box. Wrap connections with electrical tape.
4. Connect FTS cable connectors. Fully tighten 
RTD connectors, if provided.
If thermocouple (non-RTD) FTS connectors are 
provided, fully tighten connectors and slide 
connector covers over the joint.
5. Check that all equipment is properly grounded. 
See proportioner manual.
The manifold hose adapters (N, P) allow use 
of 1/4 in (6.4 mm). and 3/8 in. (9.5 mm) ID 
fluid hoses. To check adapter tightness, 
torque 1/4 in. and 3/8 in. ID hoses to:
A side (N) to 14 ft-lb (19 N•m).
B side (P) to 20 ft-lb (27 N•m).
To use 1/2 in. (13 mm) ID fluid hoses, 
remove the adapters (N, P) from the propor-
tioner fluid manifold and install them in the 
FTS or 3/8 in. ID hose inlets. Torque 1/2 in. 
ID hoses to:
A side (N) to 43 ft-lb (58 N•m).
B side (P) to 55 ft-lb (74 N•m).
M
N
P
M
4
3
12
T