Ventless Hood System 
 
Maintenance 
 
 
20 
Maintenance 
 
 
Electrocution could occur if this unit is hosed down with water. This unit is NOT 
designed for hose wash-down cleaning! Refer to scheduled maintenance below 
for proper hood cleaning. 
 
 
Electrocution could occur if power is not removed from this unit before servicing. 
Remove power at disconnect or circuit breaker BEFORE servicing hood. 
Scheduled Maintenance  
Use the following table to help manage scheduled maintenance activities. 
 
FREQUENCY PERFORMED 
BY 
PART 
ACTIVITY 
Daily 
User 
Entire Hood 
Wipe unit down with a soft rag and mild 
cleaning agent. 
 User  Condensation 
trough 
Check condensation trough. Empty if 
necessary. 
 
User 
Grease Baffle 
Clean grease baffle. If necessary, refer 
to the procedure in this manual for 
cleaning the baffle. 
Weekly 
User Particle/Odor 
Filter 
Inspect particle/odor filter. In low to 
medium volume applications, the filter 
may need replacement prior to the 
indicating light turning on. This 
condition will be evident by a strong 
odor coming from the face of the filter. 
If necessary, refer to the procedure in 
this manual for replacing the filter. 
Monthly 
User 
Door and Filter 
Interlock 
Check door and filter interlock 
operation. The unit should not operate 
with the front door open or either the 
grease baffle or particle/odor filter 
removed. Clean area between grease 
baffle and particle/odor filter.  
 
 
Injury from rotating fan blades could occur if power is not removed from this unit 
before cleaning the blower section. Remove power at disconnect or circuit breaker 
BEFORE cleaning the blower section. 
 
3 Months 
User 
Blower Section 
Clean the blower section. 
6 Months  
Authorized Service 
agent 
Fire Extinguishing 
System 
Have the fire extinguishing system 
inspected.