Bakers Pride FH-28 Manual De Usuario

Descargar
Página de 24
Ventless Hood System 
 
Maintenance 
 
 
21 
Cleaning the Grease Baffle 
 
1.  Shut down the unit. 
 
2.  Locate the thumbscrews and retaining frame at the top of the grease baffle.  
 
3.  With one hand, hold the baffle to prevent it from dropping. With the other hand, loosen the 
thumbscrews and slide the retaining frame forward.  
 
4.  Slowly lower the top end of the baffle until it clears the retaining frame.  
 
5.  Spray the grease baffle with degreasing type soap.  
 
6.  Rinse with hot water; dry, and replace in hood. 
Replacing the Particle/Odor Filter 
 
1.  Shut down the unit. 
 
2.  Open the filter door on the front of the unit by rotating the handle counter-clockwise.  
 
3.  Slide the used filter out of the unit. 
 
4.  Remove the replacement filter from the plastic bag. 
 
5.  Observing the “UP” arrows on the filter, with a hand at each front corner, carefully slide the filter 
into the unit.  
 
 
When installing a new filter, slight resistance should be observed as the filter is 
being slid into place. This resistance is generated by four (4) filter springs located 
on the bottoms of the filter slides. These springs insure a proper seal at the top of 
the filter. After a period of time it may become necessary to adjust the pressure 
that these springs provide by lifting them slightly with your fingers. 
 
6.  Close and latch the door.