Hearth & Home Technologies VRT-GR-B-CE Manual De Usuario

Descargar
Página de 44
23
Heat & Glo  •  VRTIKL-CE  •  7031-292 Rev E  •  12/07
7
Electrical Information
Battery polarity must be correct or module damage will 
occur.
CAUTION
Label all wires prior to disconnection when servicing 
controls. Wiring errors can cause improper and dangerous 
operation. Verify proper operation after servicing.
CAUTION
Shock Risk
•  Replace damaged wire with type 105° C rated wire.
•  Wire must have high temperature insulation.
WARNING
 
 
BATTERY PORT
(4 AA BATTERIES)
VALVE
PILOT
IGNITION MODULE
6VDC
ON/OFF
SWITCH
THERMOCOUPLE
BLOCK
(CONNECTED TO
BACK OF VALVE)
PILOT GAS LINE
CONNECTED TO
BACK OF VALVE
IGNITION
MODULE
(6V)
ON/OFF
WALL SWITCH
VALVE
FLAME SPARKER/
SENSOR
ANT.
REMOTE
CONTROL
A. Ignition System Wiring
•  This gas stove is equipped with an electronic ignition 
system which operates on a 6 volt system.
•  The batteries are located within the ignition module 
which is located behind the glass door assembly. A wiring 
diagram is shown in Figure 7.1.
•  The battery pack requires four AA  batteries (not included). 
Figure 7.1 
Electronic Ignition Wiring Diagram