Furuno FA-100 Manual De Usuario

Descargar
Página de 58
 18 
3.5 LAN 
Input/Output 
The FA-100 supports Ethernet based on LAN. Its protocol is 10BASE-T and the 
transmission rate is 10 Mbps. To connect the FA-100 with other equipment (such as 
a PC), use a LAN cable category 4 or higher with shield (SDT). Connect it to the 
PC with an RJ-45 connector, and connect to the FA-100 with a D-sub 9 pin 
connector, to avoid noise leakage. To use a commercial LAN cable, remove one 
connector and solder a D-sub 9 pin connector, supplied in the installation materials. 
 
TD+ 
TD-  
RD+
RD-
GND
F.GND
LAN (10B-T)
FA-100
>1>
>2>
>3>
>4>
>8>
>9>
3  RD+
6  RD-
1  TD+
2  TD-
Twisted pair cable
RJ-45 (Category 4 and higher, SDT)
 
 
 
3.6 Pilot 
Plug 
Use the twisted cable TTYCS-4 between the junction box and the pilot plug. The 
cable between the PC and the pilot plug should be prepared by the ship’s pilot. 
 
Junction box
Terminal board
TD A
TD B
RD-A
RD-B
SHIELD
TB1
>1>
>2>
>3>
>4>
>5>
>6>
>7>
>8>
>9>
J1
37  TD8-A
38  TD8-B
39  GND ISO
40  RD8-A
41  RD8-B
42  GND ISO
Pilot plug
TTYCS-4
3mm Crimp-on lug
206486-1
(AMP)
PC