3.7  Jumper Setting in the Junction Box 
Each RS-422 RX line (on the PCB 24P0031 in the junction box) has a jumper block 
with 240 ohms termination resistor. The junction box is shipped with all jumper 
blocks connected between the #3 and #4 terminals pins, terminating RX lines with 
240 ohms. Assuming that an external equipment has the output voltage of ±5 V, 
more than 21 mA of output current is required.   
If multiple equipment are connected to an output port of an external equipment, 
change to jumper block setting to between the #1 and #2 pins to reduce the load on 
the FA-100. Then, the input impedance of the RS-422 RX lines in the FA-100 
becomes more than 2.4 k ohms. 
We recommend that you leave the connection of the jumper block between #3 and 
#4 pins if only the FA-100 is connected to an external equipment. 
 
1
2
3
4
Jumper block (6 pcs)
Factory setting: #3-#4