3.  TARGET TRACKING (TT)
3-4
3.4.2
How to set an automatic acquisition zone
You can set an automatic acquisition zone to automatically track any targets entering 
the zone. The acquisition zone can be fan-shaped or polygonal. For the fan-shaped 
zone, the range is fixed at a 3-6 NM (width 0.5-1.0 NM). The polygon zone can be set 
within the range of 0.125 NM to 120 NM. (However, automatic acquisition occurs only 
between 0.1 to 24 NM (or 32 NM)). The maximum tracking range is set during the in-
stallation.
When a target enters an acquisition zone, the following occurs:
1. Click one of the boxes AZ1 or AZ2 at the right side of the screen. "AZx SET" (x=1 
or 2) appears in the box.
2. Click point A.
3. Click point B. The box now shows "AZx WORK".
Note 1: You are alerted when the capacity for automatic acquisition is 95% and 100%. 
These alerts are 522 "TT Auto ACQ 95%" and 523 "TT Auto ACQ 100%".
Note 2: If the range scale is changed to less than half of the acquisition zone, the AZ 
box shows "OUT." If the left button is pushed in this state, the acquisition alarm zone 
goes into "sleep" state (inactive).
How to sleep, deactivate an acquisition zone
Use the trackball to select the appropriate AZ box. Sleep or deactivate the acquisition 
zone as appropriate:
Sleep acquisition zone: Push the left button momentarily to remove the acquisition 
zone from the screen. The indication in the AZ box changes from "WORK" to "SLEEP." 
To reactivate and display the acquisition zone, repeat this procedure to display 
"WORK." 
Deactivate acquisition zone: Click applicable AZ box and select [Off].
How to acknowledge the acquisition zone audio alarm
Press the ALARM ACK key, or click the [Alert] box.
•  the buzzer sounds
•  the Alert 521 "TT New Target" appears in the [Alert] box
•  the symbol of the target is red and flashes
•  the AIS function is automatically turned on if it is off
000
010
020
030
040
050
060
070
080
090
100
110
120
130
140
150
160
170
180
190
200
210
220
230
240
250
260
270
280
290
300
310
320
330
340
350
A
B
X
X
X
X
Point B
Acquisition zone
Point A
Point A
Point B
Other acquisition zone examples