3.  TARGET TRACKING (TT)
3-15
3.12
TT CPA/TCPA Alarm
The TT continuously monitors the predicted range at the Closest Point of Approach 
(CPA) and predicted time to CPA (TCPA) of each TT. When the predicted CPA of any 
TT becomes smaller than the preset CPA range and its predicted TCPA less than the 
preset TCPA limit, the audio alarm sounds and the Alert 526 "CPA/TCPA" appears in 
the [Alert] box. In addition, the symbol of the offending TT is red and flashes together 
with its vector.
This feature, when used correctly, helps prevent the risk of collision by alerting you to 
threatening targets. It is important that the gain, sea clutter and rain clutter and other 
radar controls are properly adjusted.
CPA and TCPA settings must be set up properly taking into consideration the size, 
tonnage, speed, turning performance and other characteristics of own ship.
The TT CPA/TCPA alarm should not be solely relied upon to warn you of collision sit-
uations. The operator should check all aids to navigation to monitor possible collision 
situations. 
3.12.1
How to set the CPA and TCPA limits
To set the CPA and TCPA ranges, do the following:
1. If the values for CPA and TCPA are 
blank, click [CPA/TCPA] to show 
them.
2. Click the CPA indication to select 
desired CPA range (0.1-20 NM).
3. Click the TCPA indication to select 
desired TCPA time (1-60 minutes.).
3.12.2
How to enable, disable the TT CPA/
TCPA alarm
The TT CPA/TCPA alarm can be enabled or disabled 
from the TT/AIS box. Click the indication shown below 
to enable or disable the TT CPA/TCPA alarm. The 
alarm is disabled when the CPA and TCPA settings are 
not shown.
3.12.3
How to acknowledge the TT CPA/TCPA alarm
When the CPA or TCPA of a target is within the CPA and TCPA limits, the Alert 526 
"CPA/TCPA" appears in the [Alert] box and the audio alarm sounds. To acknowledge 
the alarm and silence the buzzer, push the ALARM ACK key on the Control Unit, or 
click the alert indication in the [Alert] box.
The alert in the [Alert] box and the flashing of the plotting symbol and vector continue 
until the dangerous situation is gone or you intentionally terminate tracking of the tar-
get. 
CPA setting
TCPA setting