22. Maintenance and Troubleshooting 
 
22-4 
22.3  How to Replace the Fuses 
The fuse in the radar processor unit, display unit and chart processor units protects those units from overcurrent and 
internal fault. If the power cannot be turned on, check if a fuse has blown. If it has blown, find out the cause before 
replacing the fuse. If it blows again after replacement, contact your dealer for advice. 
Unit 
Power supply 
Fuse to use 
Radar Processor Unit 
24 VDC 
20A 
100-115 VAC 
10A 
Radar Processor Unit RPU-016 
220-230 VAC 
5A 
Display Unit 
Display Unit MU-190 
100-230 VAC 
1A 
100-230 VAC 
2A 
Display Unit MU-201CR 
24 VDC 
5A 
100-230 VAC 
2A 
Display Unit MU-231CR 
24 VDC 
6A 
Display Unit MU-231 
100-230 VAC 
1.5A 
Chart Processor Unit 
Chart Processor Unit EC-1000C 
100-230 VAC  
5A 
22.4  How to Replace the Batteries 
Radar processor unit 
The GC (Gyro Converter) Board in the radar processor unit carries a battery that backs up data. The life of the 
battery is about five years. When the battery has expired, the self test results for the battery shows "NG". When this 
happens have a qualified technician replace the battery. 
Battery type 
Code no. 
CR 1/2 8.1 
000-103-769 
Chart processor unit 
The CPU Board (PCI-5S-RS-R40 or OP0100) in the chart processor unit contains a lithium battery that preserves 
data when the power is turned off. When the voltage of the battery is low the time is wrong, all default settings are 
restored, etc. When this occurs, have the battery replaced by a qualified technician, at your earliest convenience. 
CPU board type* 
Battery type 
Code no. 
PCI-5S-RS-R40 CR2032  000-159-662-10 
OP0100 CR2450 
 
* Type depends on unit production