22. Maintenance and Troubleshooting 
 
 
22-5 
22.5 Troubleshooting 
The troubleshooting table below provides common faults and the remedy with which to restore normal operation. If 
you cannot restore normal operation do not check inside the equipment - there are no user-serviceable parts inside. 
Radar troubleshooting 
If… Then… 
Remedy 
the power cannot be turned on 
 
•  power connector may have 
loosened. 
•  ship’s mains is off. 
•  fuse has blown. 
•  Check connector. 
 
•  Check ship’s mains. 
•  Replace fuse. 
the power can be turned on but 
nothing appears on the display 
 
•  brilliance is too low. 
•  the ambient temperature is less 
than 0
°
C (32
°
F). 
•  Adjust brilliance. 
•  The heater is warming the chart 
processor unit. The display 
appears in approx. 10 minutes. 
key doesn't beep when operated 
•  key beep is turned off. 
•  Turn on key beep from the menu.
Picture not updated or picture 
freeze. 
•  suspect video freeze. 30 seconds 
after the picture freezes the 
buzzer sounds, the ALARM 
ACK
 key blinks and alarm 
signal is output. 
•  Turn the power off and on again.
marks and noise appear but no 
echoes 
•  fuse may have blown. 
•  Check fuse in processor unit. 
picture does not change even 
though range is changed. 
•  suspect faulty range key or video 
freeze. 
•  Hit the RANGE key several 
times. If nothing happens, turn 
the power on and off again. 
only two index lines are displayed 
•  check index line interval setting.  •  Refer to section 2.20 
Parallel 
Index (PI) Lines
 for how to adjust 
index line interval. 
range rings are not displayed 
•  range rings are turned off. 
•  Turn on the range rings from the 
Color menu. 
ARP target is not tracked correctly 
•  sea surface reflections, etc. are 
masking ARP target. 
•  Adjust A/C SEA and A/C RAIN 
to suppress sea and rain clutters. 
sensitivity is poor 
•  suspect 2
nd
 trace echo or soiled 
radiator. 
•  Remove 2
nd
 trace echo; clean 
radiator.