Schneider Electric Altivar 12 Manual De Usuario

Descargar
Página de 133
118
BBV28581  05/2010
Applicative notes
Terminals command channel with Modbus reference channel
LO+
LO-
COM
LI1
LI2
LI3
LI4
+24
COM
AI1
5V
AO1
R1A
R1B
R1C
R
S
T
U
PA+ PC-
PO
V
W
MODBUS
Note: Please refer to Function compatibility table page 
.
1.  Connect the ground terminal to the grounding screws located below the output 
terminals. 
2.  Connect the power terminals.
3.  Connect the logic input LI1 and plug RJ45 cable to the Modbus socket.
4.  Turn on the drive without giving a run command.
5.  Assign factory settings to the drive, 
 set to 
InI.
6.  Set the motor parameters (in COnF mode) only if the factory configuration of the 
drive is not suitable.
7.  Perform an auto-tuning.
8.  Set 
 pag
 to 
SEP
.
Set 
 page 
 to 
Mdb
.
Check that 
 pag
 is set to 
tEr
.
9.  Start
ConF
CHCF
SEP
CtL-
ConF
Fr1
Mdb
CtL-
ConF
Cd1
tEr
CtL-
(a)
(a): Run Forward